Lieferung nur an Gewerbetreibende Gemäß §14 BGB, kein Verkauf an private Endverbraucher

GigE Triggerkabel, Hirose 6-POL 0,2m The Imaging Source GigE23/PWR/Trig

GigE Triggerkabel, 0,2m The Imaging Source GigE23/PWR/Trig
  • 303924
The Imaging Source GigE23/PWR/Trig GigE, Triggerkabel, Hirose 6-POL, für PSU/Cinch23/EA... mehr
Produktinformationen "GigE Triggerkabel, Hirose 6-POL 0,2m The Imaging Source GigE23/PWR/Trig"

The Imaging Source GigE23/PWR/Trig

GigE, Triggerkabel, Hirose 6-POL, für PSU/Cinch23/EA


Das GigE Triggerkabel von The Imaging Source hat eine Länge von 20cm und bietet Anschlussmöglichkeiten von Hirose auf PSU/Cinch23/EA zur externen Triggerung.  

  • GigE Kabel
  • für: PSU/Cinch23/EA
  • Ende 1: Trigger (Trigger in), Power (Power in)
  • Ende 2: Hirose (Hirose)
  • Nur für GigE 23 und 33 Kameras
  • Länge von 0,2 m 
  • Hergestellt durch The Imaging Source

 

Trigger Anschluss: 6-Pol
Weiterführende Links zu "GigE Triggerkabel, Hirose 6-POL 0,2m The Imaging Source GigE23/PWR/Trig"
Bewertungen lesen, schreiben und diskutieren... mehr
Kundenbewertungen für "GigE Triggerkabel, Hirose 6-POL 0,2m The Imaging Source GigE23/PWR/Trig"
Bewertung schreiben
Bewertungen werden nach Überprüfung freigeschaltet.

Die mit einem * markierten Felder sind Pflichtfelder.

Trigger input - hardware and timing

Trigger input - hardware and timing 

The trigger input of The Imaging Source USB, FireWire and GigE CCD cameras is opto-coupled. It permits positive trig- ger pulses with any amplitude between 3.3 and 12 V (24 V using a series resistance of 1 kOhm). If you intend to apply higher pulses please make sure that the current lies between the limits of 3 to 12 mA.

Trigger-Kamera

The Imaging Source USB, FireWire and GigE CCD cameras offers two different modes of operation:
Free running: The cameras generate a stream of up to 60 images/s depending on their resolution. To considerably redu- ce the amount of data, the frame rate may be reduced to 30, 15, 7.5 or 3.75 images/s. The exposures length can be set in the range of 100 μs to 30 s via software. Please note, however, that the camera's clock generator determines the actual moment of exposure. Thus, it cannot be controlled externally, but measurable using the strobe output. Therefore, this mode of operation is called "free running".
Trigger: The cameras offer a trigger input to determine the moment of exposure. The exposure begins 4.8 μs after the occurrence of a trigger pulse. The length of the exposure in the range of 100 μs to 30 s can be set via software. The dura- tion of the image readout is the reciprocal of the current frame rate. Once the image readout has finished, the camera is able to accept a new trigger pulse at any time.

Trigger-Exposure
Zuletzt angesehen